The high-density fiber distribution cabinet is core infrastructure adapted to the harsh operating conditions of nuclear power plants and designed for highly reliable optical signal aggregation. Featuring high-density integration, strong environmental endurance and high safety redundancy, it is the key physical carrier for the stable operation of nuclear instrumentation & control (I&C) systems and data communication networks.
Trimite Obțineți preț
| Cabinet Material | Tablă de oțel laminată la rece | Dimensiuni exterioare (mm) | 2500 800 × × 600 | ||||||
| Capacitatea tăvii de fibre | 1,440–2,880 de nuclee | Greutate (kg) | |||||||
| Accesorii standard | |||||||||
| Nu. | Nume | Unitate | Cantitate | Nu. | Nume | Unitate | Cantitate | ||
| 1 | Corpul cabinetului | set | 1 | 6 | Ansamblu de fixare a cablurilor | set | 2 | ||
| 2 | Coliere de cablu (nailon) | Pc | 60 | 7 | Unitate de îmbinare și distribuție 1U pentru montare în rack | Pc | 30 | ||
| 3 | Șuruburi de ancorare de expansiune | Pc | 4 | 8 | |||||
| 4 | Manșon de protecție pentru îmbinări | Pc | 2880 | 9 | |||||
| 5 | Manager de cablu 1U | Pc | 15 | 10 | |||||
| accesorii optionale | |||||||||
| Nu. | Nume | Unitate | Cantitate | Nu. | Nume | Unitate | Cantitate | ||
| 1 | Pigtail SC cu 12 fire inclus | Pc | 120 | 4 | Adaptor SC | Pc | 1440 | ||
| 2 | Pigtail FC cu 12 nuclee inclus | Pc | 120 | 5 | FC Adaptor | Pc | 1440 | ||
| 3 | Pigtail LC cu 12 fire integrat | Pc | 240 | 6 | Adaptor LC Duplex | Pc | 1440 | ||
Indicatori ai mediului de operare:
Temperatura de funcționare: -40 ℃ ~ + 85 ℃
Temperatura de depozitare: -40℃ ~ +85℃
Umiditate relativă de funcționare: ≤85% (la +30℃)
Umiditate relativă la depozitare: ≤90%–96% (la 40℃±2℃)
Presiune atmosferică: 70–106 kPa
Scenarii tipice de aplicare:
Nuclear island I&C equipment room: centrally deployed in core controlled areas such as the HF building and the 220kV switchyard, it carries massive optical signal aggregation of the reactor I&C system, providing low-loss splicing, dispatching and full-link protection between trunk optical cables and I&C equipment, and completely avoiding the impact of strong electromagnetic interference on critical control signals.
Nuclear power data center equipment room: the high-density LC interface model meets 10G and 400G high-speed transmission requirements, supporting high-bandwidth data transmission for the nuclear power production management system and safety monitoring platform, with over 30% port redundancy reserved to meet expansion needs across the plant’s 60-year full life cycle.
Weak-current rooms of nuclear auxiliary buildings: it centrally manages the fiber links of subsystems such as video surveillance, security access control and environmental monitoring within the plant area, avoiding crossover confusion among links and greatly reducing troubleshooting time.
Notă: Specificațiile pot fi modificate fără notificare prealabilă pentru îmbunătățirea produsului.
Este potrivit pentru diverse scenarii de consum de energie, cum ar fi clădiri rezidențiale și clădiri de birouri comerciale.